Commit c2215294c76ebb77e6f1e74232f2908ebb1d9951
1 parent
39060413
Reorder EasyOpenTherm.h by moving all enum class constants below, so the public …
…class member functions of OpenTherm are more visible, because this is the main API!
Showing
1 changed file
with
85 additions
and
61 deletions
src/EasyOpenTherm.h
| ... | ... | @@ -28,8 +28,8 @@ |
| 28 | 28 | #include <Arduino.h> |
| 29 | 29 | |
| 30 | 30 | |
| 31 | -class OTDataLinkLayer; // Foreward declaration | |
| 32 | -class OTPhysicalLayer; // Foreward declaration | |
| 31 | +class OTDataLinkLayer; // Forward declaration | |
| 32 | +class OTPhysicalLayer; // Forward declaration | |
| 33 | 33 | |
| 34 | 34 | |
| 35 | 35 | class OpenTherm { |
| ... | ... | @@ -47,6 +47,46 @@ public: |
| 47 | 47 | uint8_t & secondaryFlags); |
| 48 | 48 | |
| 49 | 49 | |
| 50 | + enum class READ_WRITE_DATA_ID; // Forward declaration of DATA-IDs that can be used to write the MSB (Most ignificant Byte) to the boiler and read the LSB from it. | |
| 51 | + enum class READ_DATA_ID; // Forward declaration of DATA-IDs that can be used to read values from the boiler | |
| 52 | + enum class WRITE_DATA_ID; // Forward declaration of DATA-IDs that can be used to write values to the boiler | |
| 53 | + enum class ERROR_CODES; // Forward declaration of ERROR_CODES, like timeouts, returned through the physical layer | |
| 54 | + | |
| 55 | + | |
| 56 | + bool read(READ_DATA_ID msgID, | |
| 57 | + uint16_t & value); | |
| 58 | + | |
| 59 | + bool read(READ_DATA_ID msgID, | |
| 60 | + int16_t & value); | |
| 61 | + | |
| 62 | + bool read(READ_DATA_ID msgID, | |
| 63 | + uint8_t & valueMSB, | |
| 64 | + uint8_t & valueLSB); | |
| 65 | + | |
| 66 | + bool read(READ_DATA_ID msgID, | |
| 67 | + int8_t & valueMSB, | |
| 68 | + int8_t & valueLSB); | |
| 69 | + | |
| 70 | + bool read(READ_DATA_ID msgID, | |
| 71 | + float & value); | |
| 72 | + | |
| 73 | + bool write(WRITE_DATA_ID msgID, | |
| 74 | + uint16_t value); | |
| 75 | + | |
| 76 | + bool write(WRITE_DATA_ID msgID, | |
| 77 | + uint8_t valueMSB, | |
| 78 | + uint8_t valueLSB); | |
| 79 | + | |
| 80 | + bool write(WRITE_DATA_ID msgID, | |
| 81 | + float value); | |
| 82 | + | |
| 83 | + bool readWrite(READ_WRITE_DATA_ID msgID, | |
| 84 | + uint8_t valueMSB, | |
| 85 | + uint8_t & valueLSB); | |
| 86 | + | |
| 87 | + ERROR_CODES error(); | |
| 88 | + | |
| 89 | + | |
| 50 | 90 | enum class READ_WRITE_DATA_ID { |
| 51 | 91 | // Class 1 : Control and Status Information |
| 52 | 92 | STATUS = 0, // flag8, flag8 Mandatory; Primary status, secondary status |
| ... | ... | @@ -222,6 +262,8 @@ public: |
| 222 | 262 | }; |
| 223 | 263 | |
| 224 | 264 | |
| 265 | + // Flags used by ::status(primaryFlags, secondaryFlags); The flags starting with PRIMARY_ are sent from the thermostat to the boiler and the flgas starting with SECONDARY_ are received | |
| 266 | + // from the boiler | |
| 225 | 267 | enum class STATUS_FLAGS { |
| 226 | 268 | // Primary device is MSB |
| 227 | 269 | PRIMARY_CH_ENABLE = (0b00000001), // CH is Central Heating |
| ... | ... | @@ -241,6 +283,18 @@ public: |
| 241 | 283 | }; |
| 242 | 284 | |
| 243 | 285 | |
| 286 | + // Configuration flags returned by calling ::read(OpenTherm::READ_DATA_ID::SECONDARY_CONFIGURATION, configurationFlags, memberID); | |
| 287 | + enum class CONFIGURATION_FLAGS { | |
| 288 | + SECONDARY_DHW_PRESENT = (0b00000001), | |
| 289 | + SECONDARY_CONTROL_TYPE = (0b00000010), | |
| 290 | + SECONDARY_COOLING = (0b00000100), | |
| 291 | + SECONDARY_DHW = (0b00001000), | |
| 292 | + SECONDARY_LOW_OFF_PUMP_CTRL = (0b00010000), | |
| 293 | + SECONDARY_CH2_PRESENT = (0b00100000), | |
| 294 | + }; | |
| 295 | + | |
| 296 | + | |
| 297 | + // A few known member IDs returned by calling ::read(OpenTherm::READ_DATA_ID::SECONDARY_CONFIGURATION, configurationFlags, memberID); | |
| 244 | 298 | enum MEMBER_IDS: uint8_t { // May be extended with other manufacturer OpenTherm member IDs. Maybe incorrect |
| 245 | 299 | AWB = 2, |
| 246 | 300 | BRINK = 2, |
| ... | ... | @@ -266,6 +320,7 @@ public: |
| 266 | 320 | }; |
| 267 | 321 | |
| 268 | 322 | |
| 323 | + // Fault flags returned by calling ::read(OpenTherm::READ_DATA_ID::FAULT_FLAGS, faultFlags, OEMFaultCode); | |
| 269 | 324 | enum class FAULT_FLAGS { |
| 270 | 325 | SERVICE_REQUEST = (0b00000001), |
| 271 | 326 | LOCKOUT_RESET = (0b00000010), |
| ... | ... | @@ -276,16 +331,7 @@ public: |
| 276 | 331 | }; |
| 277 | 332 | |
| 278 | 333 | |
| 279 | - enum class CONFIGURATION_FLAGS { | |
| 280 | - SECONDARY_DHW_PRESENT = (0b00000001), | |
| 281 | - SECONDARY_CONTROL_TYPE = (0b00000010), | |
| 282 | - SECONDARY_COOLING = (0b00000100), | |
| 283 | - SECONDARY_DHW = (0b00001000), | |
| 284 | - SECONDARY_LOW_OFF_PUMP_CTRL = (0b00010000), | |
| 285 | - SECONDARY_CH2_PRESENT = (0b00100000), | |
| 286 | - }; | |
| 287 | - | |
| 288 | - | |
| 334 | + // Remote parameter flags returned by calling ::read(OpenTherm::READ_DATA_ID::REMOTE_PARAMETER, remoteParameterTEFlags, remoteParameterRWFlags); | |
| 289 | 335 | enum class REMOTE_PARAMETER_FLAGS { |
| 290 | 336 | TRANSFER_ENABLE_DHW_SETPOINT = (0b00000001), |
| 291 | 337 | TRANSFER_ENABLE_MAX_CH_SETPOINT = (0b00000010), |
| ... | ... | @@ -295,18 +341,23 @@ public: |
| 295 | 341 | }; |
| 296 | 342 | |
| 297 | 343 | |
| 344 | + | |
| 345 | + // Remote parameter flags returned by calling ::read(OpenTherm::READ_DATA_ID::REMOTE_OVERRIDE_FUNCTION, reserved, remoteOverrideFlags); | |
| 298 | 346 | enum class REMOTE_OVERRIDE_FLAGS { |
| 299 | 347 | MANUAL_CHANGE_PRIORITY = (0b00000001), |
| 300 | 348 | REMOTE_CHANGE_PRIORITY = (0b00000010), |
| 301 | 349 | }; |
| 302 | 350 | |
| 303 | 351 | |
| 352 | + // Remote parameter flags returned by calling ::readWrite(OpenTherm::READ_WRITE_DATA_ID::COMMAND_CODE, remoteCommand, cmdResponseCode); | |
| 304 | 353 | enum class REMOTE_COMMANDS { |
| 305 | 354 | BLOR = (1), // Boiler Lock-out Reset command |
| 306 | 355 | CHWF = (2), // CH water filling |
| 307 | 356 | }; |
| 308 | 357 | |
| 309 | 358 | |
| 359 | + // Flags used by ::readWrite(OpenTherm::READ_WRITE_DATA_ID::HVAC_STATUS, primaryFlags, secondaryFlags); The flags starting with PRIMARY_ are sent from the thermostat to the HVAC | |
| 360 | + // and the flags starting with SECONDARY_ are received from the HVAC. This is comparable to the ::status() call for a boiler. | |
| 310 | 361 | enum class HVAC_STATUS_FLAGS { |
| 311 | 362 | // Primary device is MSB |
| 312 | 363 | PRIMARY_VENTILATION_ENABLE = (0b00000001), |
| ... | ... | @@ -347,48 +398,17 @@ public: |
| 347 | 398 | }; |
| 348 | 399 | |
| 349 | 400 | |
| 401 | + // ::error(); returns the result of the latest call to ::read();, ::write(); or ::readWrite(); | |
| 350 | 402 | enum class ERROR_CODES { |
| 351 | - OK, | |
| 352 | - UNKNOWN_DATA_ID, | |
| 353 | - INVALID_DATA, | |
| 354 | - SEND_TIMEOUT, | |
| 355 | - RECEIVE_TIMEOUT, | |
| 356 | - PARITY_ERROR, | |
| 357 | - UNKNOWN_ERROR, | |
| 403 | + OK, // Everything is OK | |
| 404 | + UNKNOWN_DATA_ID, // The DATA-ID sent by the primary to the secondary is not supported by the secondary | |
| 405 | + INVALID_DATA, // The DATA-ID sent by the primary to the secondary is supported but the sent value is out of bounds | |
| 406 | + SEND_TIMEOUT, // The primary could not send within timeout period (should not occur if timeouts are reasonable) | |
| 407 | + RECEIVE_TIMEOUT, // The secondary did not respond within timeout period | |
| 408 | + PARITY_ERROR, // The secondary's response had a parity error | |
| 409 | + UNKNOWN_ERROR, // Unknown error (should not occur) | |
| 358 | 410 | }; |
| 359 | 411 | |
| 360 | - bool read(READ_DATA_ID msgID, | |
| 361 | - uint16_t & value); | |
| 362 | - | |
| 363 | - bool read(READ_DATA_ID msgID, | |
| 364 | - int16_t & value); | |
| 365 | - | |
| 366 | - bool read(READ_DATA_ID msgID, | |
| 367 | - uint8_t & valueMSB, | |
| 368 | - uint8_t & valueLSB); | |
| 369 | - | |
| 370 | - bool read(READ_DATA_ID msgID, | |
| 371 | - int8_t & valueMSB, | |
| 372 | - int8_t & valueLSB); | |
| 373 | - | |
| 374 | - bool read(READ_DATA_ID msgID, | |
| 375 | - float & value); | |
| 376 | - | |
| 377 | - bool write(WRITE_DATA_ID msgID, | |
| 378 | - uint16_t value); | |
| 379 | - | |
| 380 | - bool write(WRITE_DATA_ID msgID, | |
| 381 | - uint8_t valueMSB, | |
| 382 | - uint8_t valueLSB); | |
| 383 | - | |
| 384 | - bool write(WRITE_DATA_ID msgID, | |
| 385 | - float value); | |
| 386 | - | |
| 387 | - bool readWrite(READ_WRITE_DATA_ID msgID, | |
| 388 | - uint8_t valueMSB, | |
| 389 | - uint8_t & valueLSB); | |
| 390 | - | |
| 391 | - ERROR_CODES error(); | |
| 392 | 412 | |
| 393 | 413 | private: |
| 394 | 414 | bool _execute(OTDataLinkLayer & data); |
| ... | ... | @@ -407,17 +427,8 @@ private: |
| 407 | 427 | |
| 408 | 428 | class OTDataLinkLayer { |
| 409 | 429 | public: |
| 410 | - enum class MSG_TYPE { | |
| 411 | - PRIMARY_TO_SECONDARY_READ_DATA = (0b0000000UL << 24), // value >> 28 := 0 | |
| 412 | - PRIMARY_TO_SECONDARY_WRITE_DATA = (0b0010000UL << 24), // value >> 28 := 1 | |
| 413 | - PRIMARY_TO_SECONDARY_INVALID_DATA = (0b0100000UL << 24), // value >> 28 := 2 | |
| 414 | - PRIMARY_TO_SECONDARY_RESERVED = (0b0110000UL << 24), // value >> 28 := 3 | |
| 430 | + enum class MSG_TYPE; // Forward declaration | |
| 415 | 431 | |
| 416 | - SECONDARY_TO_PRIMARY_READ_ACK = (0b1000000UL << 24), // value >> 28 := 4 | |
| 417 | - SECONDARY_TO_PRIMARY_WRITE_ACK = (0b1010000UL << 24), // value >> 28 := 5 | |
| 418 | - SECONDARY_TO_PRIMARY_DATA_INVALID = (0b1100000UL << 24), // value >> 28 := 6 | |
| 419 | - SECONDARY_TO_PRIMARY_UNKNOWN_DATA_ID = (0b1110000UL << 24) // value >> 28 := 7 | |
| 420 | - }; | |
| 421 | 432 | |
| 422 | 433 | OTDataLinkLayer(); |
| 423 | 434 | |
| ... | ... | @@ -454,6 +465,19 @@ public: |
| 454 | 465 | |
| 455 | 466 | bool unknownDataID(); |
| 456 | 467 | |
| 468 | + | |
| 469 | + enum class MSG_TYPE { | |
| 470 | + PRIMARY_TO_SECONDARY_READ_DATA = (0b0000000UL << 24), // value >> 28 := 0 | |
| 471 | + PRIMARY_TO_SECONDARY_WRITE_DATA = (0b0010000UL << 24), // value >> 28 := 1 | |
| 472 | + PRIMARY_TO_SECONDARY_INVALID_DATA = (0b0100000UL << 24), // value >> 28 := 2 | |
| 473 | + PRIMARY_TO_SECONDARY_RESERVED = (0b0110000UL << 24), // value >> 28 := 3 | |
| 474 | + | |
| 475 | + SECONDARY_TO_PRIMARY_READ_ACK = (0b1000000UL << 24), // value >> 28 := 4 | |
| 476 | + SECONDARY_TO_PRIMARY_WRITE_ACK = (0b1010000UL << 24), // value >> 28 := 5 | |
| 477 | + SECONDARY_TO_PRIMARY_DATA_INVALID = (0b1100000UL << 24), // value >> 28 := 6 | |
| 478 | + SECONDARY_TO_PRIMARY_UNKNOWN_DATA_ID = (0b1110000UL << 24) // value >> 28 := 7 | |
| 479 | + }; | |
| 480 | + | |
| 457 | 481 | private: |
| 458 | 482 | uint32_t _frame; |