... ... @@ -28,8 +28,8 @@
28 28 #include <Arduino.h>
29 29  
30 30  
31   -class OTDataLinkLayer; // Foreward declaration
32   -class OTPhysicalLayer; // Foreward declaration
  31 +class OTDataLinkLayer; // Forward declaration
  32 +class OTPhysicalLayer; // Forward declaration
33 33  
34 34  
35 35 class OpenTherm {
... ... @@ -47,6 +47,46 @@ public:
47 47 uint8_t & secondaryFlags);
48 48  
49 49  
  50 + enum class READ_WRITE_DATA_ID; // Forward declaration of DATA-IDs that can be used to write the MSB (Most ignificant Byte) to the boiler and read the LSB from it.
  51 + enum class READ_DATA_ID; // Forward declaration of DATA-IDs that can be used to read values from the boiler
  52 + enum class WRITE_DATA_ID; // Forward declaration of DATA-IDs that can be used to write values to the boiler
  53 + enum class ERROR_CODES; // Forward declaration of ERROR_CODES, like timeouts, returned through the physical layer
  54 +
  55 +
  56 + bool read(READ_DATA_ID msgID,
  57 + uint16_t & value);
  58 +
  59 + bool read(READ_DATA_ID msgID,
  60 + int16_t & value);
  61 +
  62 + bool read(READ_DATA_ID msgID,
  63 + uint8_t & valueMSB,
  64 + uint8_t & valueLSB);
  65 +
  66 + bool read(READ_DATA_ID msgID,
  67 + int8_t & valueMSB,
  68 + int8_t & valueLSB);
  69 +
  70 + bool read(READ_DATA_ID msgID,
  71 + float & value);
  72 +
  73 + bool write(WRITE_DATA_ID msgID,
  74 + uint16_t value);
  75 +
  76 + bool write(WRITE_DATA_ID msgID,
  77 + uint8_t valueMSB,
  78 + uint8_t valueLSB);
  79 +
  80 + bool write(WRITE_DATA_ID msgID,
  81 + float value);
  82 +
  83 + bool readWrite(READ_WRITE_DATA_ID msgID,
  84 + uint8_t valueMSB,
  85 + uint8_t & valueLSB);
  86 +
  87 + ERROR_CODES error();
  88 +
  89 +
50 90 enum class READ_WRITE_DATA_ID {
51 91 // Class 1 : Control and Status Information
52 92 STATUS = 0, // flag8, flag8 Mandatory; Primary status, secondary status
... ... @@ -222,6 +262,8 @@ public:
222 262 };
223 263  
224 264  
  265 + // Flags used by ::status(primaryFlags, secondaryFlags); The flags starting with PRIMARY_ are sent from the thermostat to the boiler and the flgas starting with SECONDARY_ are received
  266 + // from the boiler
225 267 enum class STATUS_FLAGS {
226 268 // Primary device is MSB
227 269 PRIMARY_CH_ENABLE = (0b00000001), // CH is Central Heating
... ... @@ -241,6 +283,18 @@ public:
241 283 };
242 284  
243 285  
  286 + // Configuration flags returned by calling ::read(OpenTherm::READ_DATA_ID::SECONDARY_CONFIGURATION, configurationFlags, memberID);
  287 + enum class CONFIGURATION_FLAGS {
  288 + SECONDARY_DHW_PRESENT = (0b00000001),
  289 + SECONDARY_CONTROL_TYPE = (0b00000010),
  290 + SECONDARY_COOLING = (0b00000100),
  291 + SECONDARY_DHW = (0b00001000),
  292 + SECONDARY_LOW_OFF_PUMP_CTRL = (0b00010000),
  293 + SECONDARY_CH2_PRESENT = (0b00100000),
  294 + };
  295 +
  296 +
  297 + // A few known member IDs returned by calling ::read(OpenTherm::READ_DATA_ID::SECONDARY_CONFIGURATION, configurationFlags, memberID);
244 298 enum MEMBER_IDS: uint8_t { // May be extended with other manufacturer OpenTherm member IDs. Maybe incorrect
245 299 AWB = 2,
246 300 BRINK = 2,
... ... @@ -266,6 +320,7 @@ public:
266 320 };
267 321  
268 322  
  323 + // Fault flags returned by calling ::read(OpenTherm::READ_DATA_ID::FAULT_FLAGS, faultFlags, OEMFaultCode);
269 324 enum class FAULT_FLAGS {
270 325 SERVICE_REQUEST = (0b00000001),
271 326 LOCKOUT_RESET = (0b00000010),
... ... @@ -276,16 +331,7 @@ public:
276 331 };
277 332  
278 333  
279   - enum class CONFIGURATION_FLAGS {
280   - SECONDARY_DHW_PRESENT = (0b00000001),
281   - SECONDARY_CONTROL_TYPE = (0b00000010),
282   - SECONDARY_COOLING = (0b00000100),
283   - SECONDARY_DHW = (0b00001000),
284   - SECONDARY_LOW_OFF_PUMP_CTRL = (0b00010000),
285   - SECONDARY_CH2_PRESENT = (0b00100000),
286   - };
287   -
288   -
  334 + // Remote parameter flags returned by calling ::read(OpenTherm::READ_DATA_ID::REMOTE_PARAMETER, remoteParameterTEFlags, remoteParameterRWFlags);
289 335 enum class REMOTE_PARAMETER_FLAGS {
290 336 TRANSFER_ENABLE_DHW_SETPOINT = (0b00000001),
291 337 TRANSFER_ENABLE_MAX_CH_SETPOINT = (0b00000010),
... ... @@ -295,18 +341,23 @@ public:
295 341 };
296 342  
297 343  
  344 +
  345 + // Remote parameter flags returned by calling ::read(OpenTherm::READ_DATA_ID::REMOTE_OVERRIDE_FUNCTION, reserved, remoteOverrideFlags);
298 346 enum class REMOTE_OVERRIDE_FLAGS {
299 347 MANUAL_CHANGE_PRIORITY = (0b00000001),
300 348 REMOTE_CHANGE_PRIORITY = (0b00000010),
301 349 };
302 350  
303 351  
  352 + // Remote parameter flags returned by calling ::readWrite(OpenTherm::READ_WRITE_DATA_ID::COMMAND_CODE, remoteCommand, cmdResponseCode);
304 353 enum class REMOTE_COMMANDS {
305 354 BLOR = (1), // Boiler Lock-out Reset command
306 355 CHWF = (2), // CH water filling
307 356 };
308 357  
309 358  
  359 + // Flags used by ::readWrite(OpenTherm::READ_WRITE_DATA_ID::HVAC_STATUS, primaryFlags, secondaryFlags); The flags starting with PRIMARY_ are sent from the thermostat to the HVAC
  360 + // and the flags starting with SECONDARY_ are received from the HVAC. This is comparable to the ::status() call for a boiler.
310 361 enum class HVAC_STATUS_FLAGS {
311 362 // Primary device is MSB
312 363 PRIMARY_VENTILATION_ENABLE = (0b00000001),
... ... @@ -347,48 +398,17 @@ public:
347 398 };
348 399  
349 400  
  401 + // ::error(); returns the result of the latest call to ::read();, ::write(); or ::readWrite();
350 402 enum class ERROR_CODES {
351   - OK,
352   - UNKNOWN_DATA_ID,
353   - INVALID_DATA,
354   - SEND_TIMEOUT,
355   - RECEIVE_TIMEOUT,
356   - PARITY_ERROR,
357   - UNKNOWN_ERROR,
  403 + OK, // Everything is OK
  404 + UNKNOWN_DATA_ID, // The DATA-ID sent by the primary to the secondary is not supported by the secondary
  405 + INVALID_DATA, // The DATA-ID sent by the primary to the secondary is supported but the sent value is out of bounds
  406 + SEND_TIMEOUT, // The primary could not send within timeout period (should not occur if timeouts are reasonable)
  407 + RECEIVE_TIMEOUT, // The secondary did not respond within timeout period
  408 + PARITY_ERROR, // The secondary's response had a parity error
  409 + UNKNOWN_ERROR, // Unknown error (should not occur)
358 410 };
359 411  
360   - bool read(READ_DATA_ID msgID,
361   - uint16_t & value);
362   -
363   - bool read(READ_DATA_ID msgID,
364   - int16_t & value);
365   -
366   - bool read(READ_DATA_ID msgID,
367   - uint8_t & valueMSB,
368   - uint8_t & valueLSB);
369   -
370   - bool read(READ_DATA_ID msgID,
371   - int8_t & valueMSB,
372   - int8_t & valueLSB);
373   -
374   - bool read(READ_DATA_ID msgID,
375   - float & value);
376   -
377   - bool write(WRITE_DATA_ID msgID,
378   - uint16_t value);
379   -
380   - bool write(WRITE_DATA_ID msgID,
381   - uint8_t valueMSB,
382   - uint8_t valueLSB);
383   -
384   - bool write(WRITE_DATA_ID msgID,
385   - float value);
386   -
387   - bool readWrite(READ_WRITE_DATA_ID msgID,
388   - uint8_t valueMSB,
389   - uint8_t & valueLSB);
390   -
391   - ERROR_CODES error();
392 412  
393 413 private:
394 414 bool _execute(OTDataLinkLayer & data);
... ... @@ -407,17 +427,8 @@ private:
407 427  
408 428 class OTDataLinkLayer {
409 429 public:
410   - enum class MSG_TYPE {
411   - PRIMARY_TO_SECONDARY_READ_DATA = (0b0000000UL << 24), // value >> 28 := 0
412   - PRIMARY_TO_SECONDARY_WRITE_DATA = (0b0010000UL << 24), // value >> 28 := 1
413   - PRIMARY_TO_SECONDARY_INVALID_DATA = (0b0100000UL << 24), // value >> 28 := 2
414   - PRIMARY_TO_SECONDARY_RESERVED = (0b0110000UL << 24), // value >> 28 := 3
  430 + enum class MSG_TYPE; // Forward declaration
415 431  
416   - SECONDARY_TO_PRIMARY_READ_ACK = (0b1000000UL << 24), // value >> 28 := 4
417   - SECONDARY_TO_PRIMARY_WRITE_ACK = (0b1010000UL << 24), // value >> 28 := 5
418   - SECONDARY_TO_PRIMARY_DATA_INVALID = (0b1100000UL << 24), // value >> 28 := 6
419   - SECONDARY_TO_PRIMARY_UNKNOWN_DATA_ID = (0b1110000UL << 24) // value >> 28 := 7
420   - };
421 432  
422 433 OTDataLinkLayer();
423 434  
... ... @@ -454,6 +465,19 @@ public:
454 465  
455 466 bool unknownDataID();
456 467  
  468 +
  469 + enum class MSG_TYPE {
  470 + PRIMARY_TO_SECONDARY_READ_DATA = (0b0000000UL << 24), // value >> 28 := 0
  471 + PRIMARY_TO_SECONDARY_WRITE_DATA = (0b0010000UL << 24), // value >> 28 := 1
  472 + PRIMARY_TO_SECONDARY_INVALID_DATA = (0b0100000UL << 24), // value >> 28 := 2
  473 + PRIMARY_TO_SECONDARY_RESERVED = (0b0110000UL << 24), // value >> 28 := 3
  474 +
  475 + SECONDARY_TO_PRIMARY_READ_ACK = (0b1000000UL << 24), // value >> 28 := 4
  476 + SECONDARY_TO_PRIMARY_WRITE_ACK = (0b1010000UL << 24), // value >> 28 := 5
  477 + SECONDARY_TO_PRIMARY_DATA_INVALID = (0b1100000UL << 24), // value >> 28 := 6
  478 + SECONDARY_TO_PRIMARY_UNKNOWN_DATA_ID = (0b1110000UL << 24) // value >> 28 := 7
  479 + };
  480 +
457 481 private:
458 482 uint32_t _frame;
459 483  
... ...