Logo white

Peter M. Groen / libmodbus

Sign in
  • Sign in
  • Project
  • Files
  • Commits
  • Network
  • Graphs
  • Milestones
  • Issues 0
  • Merge Requests 0
  • Labels
  • Wiki
  • Commits 855
  • Compare
  • Branches 1
  • Tags 0
  • libmodbus
  • tests
  • unit-test-client.c
03 Nov, 2010
1 commit
  • Rename modbus_[listen|accept] to modbus_tcp_[listen|accept] ...
    b8c0558c
    These functions have no meaning in RTU so it's better to specialize
    the names and remove them from the backend.
    
    - remove the functions from the backend
    - update tests to handle RTU mode (master and slave)
    - add command line options to tests (rtu or tcp)
    Stéphane Raimbault authored
    2010-11-03 08:07:56 +0100  
    Browse File »

29 Oct, 2010
1 commit
  • Add strlcpy if not available to enhance copy of device string ...
    4ac3cc37
    - check strlcpy in configure.ac
    - test for empty device string
    - test truncated device string
    Stéphane Raimbault authored
    2010-10-29 21:30:27 +0200  
    Browse File »

28 Oct, 2010
1 commit
  • Remove the slave ID argument of modbus_new_rtu() ...
    525aadb2
    modbus_set_slave must be used to set the slave ID of the remote
    device to talk in master mode and to set the internal slave ID in
    slave mode.
    
    If you talk to several devices, you need to call modbus_set_slave
    each time the following requests must be sent to another device.
    Stéphane Raimbault authored
    2010-10-28 19:06:42 +0200  
    Browse File »

10 Aug, 2010
3 commits
  • Rename to modbus_read_and_write_registers to follow the new API
    bf763c96
    Stéphane Raimbault authored
    2010-08-10 08:51:26 +0200  
    Browse File »
  • New read and write registers function
    9a2733e7
    Hannu Vuolasaho authored
    2010-08-10 08:39:54 +0200  
    Browse File »
  • Replace MODBUS_MAX_* by MODBUS_MAX_[READ|WRITE]_*
    a2e16a16
    Hannu Vuolasaho authored
    2010-08-10 08:26:47 +0200  
    Browse File »

23 Jul, 2010
3 commits
  • Implement report slave ID on server side ...
    4d3bf7be
    - return only useful data client side
    - available in TCP when a gateway to RTU is used
    - need to add isolated handling of indication/confirmation messages
    Stéphane Raimbault authored
    2010-07-23 00:27:49 +0200  
    Browse File »
  • Add unit test to read 0 registers
    a0c660fe
    Stéphane Raimbault authored
    2010-07-23 00:27:49 +0200  
    Browse File »
  • Rename slave to server and master to client
    3593d5ad
    Stéphane Raimbault authored
    2010-07-23 00:27:49 +0200  
    Browse File »