Examples for OpenTherm Arduino ESP32 Library

Several examples are given, all fully functional, from very basic to advanced. The first thing you should always do is to run Test_Boiler_Communication.ino or Test_HVAC_Communication.ino, to make sure your OpenTherm controller board or OpenTherm controller Shield is correctly wired, the right GPIO pins are configured and the 'secondary', i.e. the boiler or HVAC, is responding to the requests of the 'primary', i.e. the thermostat.

Test_Boiler_Communication.ino and Test_HVAC_Communication.ino

Basic test of your setup. If everything is OK, you will see:

Your setup is working! A frame was send to the boiler and the boiler responded with a valid frame.

together with some more information. If you do not see this line:

  • Is the EasyOpenTherm board correctly wired? Is the pin you defined with #define OT_RX_PIN connected to TxD of the board? Is the pin you defined #define OT_TX_PIN connected to RxD of the board? Is GND of the EasyOpenTherm your connected to a GND pin of your ESP32 or ESP8266 board? Is 3v3 of the EasyOpenTherm board connected to 3v3 of your ESP32 or ESP8266 board? For an EasyOpenTherm shield you can skip this step.
  • For the EasyOpenTherm board, are the pins marked OT connected to the thermostat wires of your boiler? For the EasyOpenTherm shield, are the thermostat wires of your boiler connected to the green screw terminal?
  • Did you remove the "normal" thermostat? (The OpenTherm protocol supports only one thermostat on the bus)
  • Does the pin you selected with #define OT_RX_PIN support interrupts?
  • Does the pin you selected with #define OT_TX_PIN support OUTPUT (not input only)
  • Does your boiler support the OpenTherm protocol?

The Test_HVAC_Communication.ino program is not tested because I do not own such a device. You should see:

Your setup is working! A frame was send to the HVAC and the HVAC responded with a valid frame.

If you do not see this line do the same checks as above for the boiler.

MQTT_Advanced_Thermostat.ino

Home Assistant logo Home Assistant Thermostat Card MQTT logo

If you already know how to flash an microcontroller from the Arduino IDE and already have Home Assistant installed with the MQTT integration, the thermostat should be up and running in minutes!

The Advanced_Thermostat.ino example is specially designed for Home Assistant with a MQTT integration. This example can also be used with other home automation software that supports MQTT. although auto discovery of the thermostat and the sensors will not work in this case.

Prerequisites

  • An OpenTherm controller board or shield correctly connected to the thermostat wires
  • Home Assistant installed
  • A MQTT broker, preferably Mosquitto
  • The MQTT integration added to Home Assistant
  • The Arduino IDE installed on your computer
  • An ESP32, e.g. an ESP32-S2 mini, flashed with Advanced_Thermostat.ino (can be opened from the examples: File -> Examples, scroll all the way down to 'EasyOpenTherm' and select 'Advanced_Thermostat'). Before flashing, first set your WiFi network name and password in the progam, and your MQTT broker hostname or IP address, MQTT user name and MQTT password
  • A thermometer in Home Assistant, and an automation to forward the room temperature to the Thermostat using a Home Assistant Automation (Settings -> Automations & Scenes -> + Create Automation. Start with an empty automation, click the three dots in the upper right corner and select: Edit in YAML). Add: alias: Publish room temperature description: Publish room temperature to MQTT Climate state trigger: - platform: state entity_id: sensor.temperature_humidity_sensor_2258_temperature action: - service: mqtt.publish data: topic: Metriot/EasyOpenTherm/22b5ea03f784/climate/state payload: "{\"temperature\":{{ trigger.to_state.state }}}" mode: single Replace the entity_id with the id of your thermometer and replace '22b5ea03f784' number in the topic with your number (can be found in the logging)

The thermostat (Climate) integration is automatically added to Home Assistant, together with several sensors.

Thermostat behaviour

  • The thermostat is enabled in Home Assistant if it communicates with an OpenTherm boiler
  • The thermostat shows the room temperature if it receives temperature updates over MQTT (and is enabled, see previous step)
  • The desired room temperature, the room temperature setpoint, can be set by turning the dial
  • As long as the thermostat is switched off it will never start heating
  • Press the flame below the dial to turn the thermostat on
  • If the room temperature is below setpoint (minus a 0.1 ºC deadzone) the boiler will start heating
  • If the boiler switches off after running for a while, it will stay off for at least 10 minutes (Anti Hunting interval)
  • If the thermostat does not receive temperature updates for more than 15 minutes, it will switch to 'idle', to prevent your house from being heated if the thermometer fails

Sensors

The following sensors are always added:

  • EasyOpenTherm xxxx Boiler Setpoint: showing the setpoint of the central heating boiler water temperature
  • EasyOpenTherm xxxx Thermostat RSSI: showing the WiFi signal strength of the connection with the router
  • EasyOpenTherm xxxx Boiler Flame: showing 'on' if the boiler is running for Central Heating or Domestic Hot Water, 'off' otherwise

The following sensors are conditionally added:

  • EasyOpenTherm xxxx Boiler Domestic Hot Water: is only added if the boiler supports DHW, showing 'on' if the boiler is running for DHW
  • EasyOpenTherm xxxx Boiler Return Temperature: is only added if a return temperature sensor value can be read using the OpenTherm interface. It shows the temperature of the water returning to the boiler
  • EasyOpenTherm xxxx Boiler Flow Temperature: is only added if a flow temperature sensor value can be read using the OpenTherm interface. It shows the temperature of the water leaving the boiler
  • EasyOpenTherm xxxx Boiler Relative modulation: is only added if the relative modulation can be read using the OpenTherm interface. It shows the percentage of the maximum power actually used
  • EasyOpenTherm xxxx Boiler Water Pressure sensor: is only added if the water pressure can be read using the OpenTherm interface. It shows the pressure of the water in the central heating circuit

Troubleshooting

  • The Thermostat does not appear in Home Assistant - Make sure that the MQTT integration is correctly installed in Home Assistant. Check if the WiFi credentials and the MQTT credentials in Advanced_Thermostat.ino are correct
  • The Thermostat does appear but it is not enabled - Check the wiring of the OpenTherm Controller to the boiler. Run Test_Boiler_Communication.ino first to check if the OpenTherm Controller can communicate with the boiler. Make sure the boiler is OpenTherm compatible.
  • The Thermostat does appear and is enabled but no room temperature (ending in ºC) is shown in the middle - The thermostat is not receiving a room temperature; check the automation: did you select the right entity_id? Did you select the right topic? Go to Settings -> Devices & Services -> core-mosquitto CONFIGURE. Fill in '#' at 'Topic to subscibe to'. Wait a while, to see a message like:
Message 42 received on Metriot/EasyOpenTherm/cc031c4e76a0/climate/state at 6:22 PM:

{
    "temperature": 17.1
}

You could blow into the thermometer to force a temperature update from the thermometer, that should inmediately appear in the MQTT messages.

Saving energy and money

The intention of the thermostat is to save energy and to save money. I can not guarantee though that this will also be the case in your setup. The thermostat can be tweaked to serve your needs by setting the options, most of these #defines are found in the main program and in ThermoStateMachine.cpp. Wrting your own thermostat software from scratch is also an option ofcourse.

Home Assistant can be used for geo fencing, smart schemes to switch the boiler on and off, or e.g. to control the temperature in each of your rooms individually!

Using Advanced_Thermostat.ino in other MQTT enabled home automation systems

The Advanced_Thermostat.ino can also be used in other MQTT enabled home automation systems. In this case the auto discovery of the Thermostat and the sensors will not work. But the thermostat can be controlled by publishing and subscribing to the right topics. In all below topics the hex number 22b5ea03f784 needs to be changed into the right number for your ESP32 or ESP8266 (all small caps)

Topics to publish to:

  • Metriot/EasyOpenTherm/22b5ea03f784/climate/state: publish the room temperature in JSON format {"temperature": 19.8}
  • Metriot/EasyOpenTherm/22b5ea03f784/mode/set: publish off to switch the thermostat off, heat to switch it on (on means: the thermostat is running and decides upon various parameters to switch your boiler on. It does not mean: start the boiler inmediately)
  • Metriot/EasyOpenTherm/22b5ea03f784/setpoint/set: publish the desired room temperature (room temperature setpoint) in plain text format, e.g. 20.8

Topics to subscribe to:

  • Metriot/EasyOpenTherm/22b5ea03f784/flame/state: to receive 'flame' updates of the format {"flame":"OFF"}
  • Metriot/EasyOpenTherm/22b5ea03f784/RSSI/state: to receive 'RSSI' updates of the format {"RSSI":-57}
  • Metriot/EasyOpenTherm/22b5ea03f784/ch_setpoint/state: to receive 'central heating setpoint' updates of the format {"ch_setpoint":10.0}
  • Metriot/EasyOpenTherm/22b5ea03f784/flow_temperature/state: to receive 'flow temperature' updates of the format {"flow_temperature":25.7} (if supported by your boiler)
  • Metriot/EasyOpenTherm/22b5ea03f784/return_temperature/state: to receive 'return temperature' updates of the format {"return_temperature":25.5} (if supported by your boiler)
  • Metriot/EasyOpenTherm/22b5ea03f784/relative_modulation/state: to receive 'relative modulation' updates of the format {"relative_modulation":0.0} (if supported by your boiler)
  • Metriot/EasyOpenTherm/22b5ea03f784/water_pressure/state: to receive 'water pressure' updates of the format {"water_pressure":2.2} (if supported by your boiler)

Modifing Advanced_Thermostat.ino for HVACs

It should be possible to modify the program to work with HVACs. It should be relatively straight forward (maybe a flag can_heat must be added, the right status should be used, the flags need adaptations and the DATA-IDs need to be changed, to name a few). I do not have a HVAC, but maybe I can help and publish a HVAC example too.

OpenTherm_Show_DATA-IDs.ino

Sends all known DATA-IDs to the secondary and shows it's response. Can be used for both boilers and HVACs, although the boiler information is more extensive. Also the data types for the HVAC calls may not be correct.

Sample output of this program for a Remeha Avanta shows the following:

Started
Request secondary services using status command:
+ Enable Domestic Hot Water (DHW)
+ Enable Central Heating (CH)
+ Enable cooling
+ Enable Outside Temperature Compensation by default

Request services from the boiler and check it's status...
Status flags is 0x00
> Flame is off

Checking each read DATA-ID. This may take some time, especially if the boiler does not respond to a DATA-ID because then the thermostat waits for a timeout of about a second for each of such a DATA-ID.
Fault flags:
> No faults;
> OEM specific fault code is 0xff
Secondary configuration:
> Domestic Hot Water (DHW) present
> Control type modulating
> Cooling NOT supported
> Domestic Hot Water (DHW) instantaneous or not-specified
> Primary low-off & pump control function allowed
> 2nd Central heating NOT present
> Remaining unknown flags 0x40
> Secondary Member ID is 11 (0x0b)
Secondary OpenTherm Version: 3.00
Secondary Product Version: 5, 20
Relative Modulation level: 0.00
Boiler water temperature (from boiler): 29.19 °C
Return water temperature (to boiler): 28.50 °C
Burner starts: unavailable
Central Heating pump starts: unavailable
Domestic Hot water (DHW) pump/valve starts: unavailable
Burner starts in Domestic Hot water (DHW) mode: unavailable
Burner operating hours: 16998 hours
Central Heating pump operating hours: 19894 hours
Domestic Hot Water (DHW) pump has been running or DHW valve has been opened for: 4304 hours
Domestic Hot Water (DHW) burner operating hours: 4583 hours
Remote parameters:
> Domestic Hot Water (DHW) setpoint transfer: enabled
> Max Central Heating (CH) setpoint transfer: enabled
> Domestic Hot Water (DHW) setpoint: read/write
> Max Central Heating (CH) setpoint: read/write
Domestic Hot Water (DHW) setpoint bounds between 40 and 50 °C
Central Heating (CH) setpoint bounds between 20 and 60 °C
Domestic Hot Water (DHW) temperature setpoint (remote parameter 1): 50.00 °C
Maximum allowable Central Heating (CH) water temperature setpoint (remote parameter 2): 60.00 °C
Number of unsuccessful burner starts: 1
Number of times flame signal was too low: 13

Basic_Thermostat_Commands.ino

Shows the most basic commands that can be sent from a thermostat (primary) to a boiler (secondary) and may also be used as inspiration for a HVAC thermostat. It sets the room temperature setpoint to a fixed value, which is not reasonable for a real thermostat. But it will start your boiler and heat up your house!