1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545
/*
 *    https://github.com/Jeroen88/EasyOpenTherm
 *    https://www.tindie.com/products/Metriot/OpenTherm-adapter/
 *
 *    EasyOpenTherm is a library to communicate with OpenTherm compatible devices
 *    Copyright (C) 2022  Jeroen Döll <info@metriot.nl>
 *
 *    This program is free software: you can redistribute it and/or modify
 *    it under the terms of the GNU General Public License as published by
 *    the Free Software Foundation, either version 3 of the License, or
 *    (at your option) any later version.
 *
 *    This program is distributed in the hope that it will be useful,
 *    but WITHOUT ANY WARRANTY; without even the implied warranty of
 *    MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
 *    GNU General Public License for more details.
 *
 *    You should have received a copy of the GNU General Public License
 *    along with this program.  If not, see <https://www.gnu.org/licenses/>.
 *
 *    Primary: thermostat
 *    Secondary: boiler or HVAC
*/


#pragma once

#include <Arduino.h>


class                     OTDataLinkLayer;                    // Forward declaration
class                     OTPhysicalLayer;                    // Forward declaration


class                     OpenTherm {
public:
                          OpenTherm(uint8_t                   rxPin,
                                    uint8_t                   txPin,
                                    time_t                    timeoutMs = 900,
                                    bool                      primary = true);

                          ~OpenTherm();

  bool                    status(uint8_t &                    secondaryFlags);

  bool                    status(uint8_t                      primaryFlags,
                                  uint8_t &                   secondaryFlags);


  enum class    READ_WRITE_DATA_ID;                           // Forward declaration of DATA-IDs that can be used to write the MSB (Most ignificant Byte) to the boiler and read the LSB from it.
  enum class    READ_DATA_ID;                                 // Forward declaration of DATA-IDs that can be used to read values from the boiler
  enum class    WRITE_DATA_ID;                                // Forward declaration of DATA-IDs that can be used to write values to the boiler
  enum class    ERROR_CODES;                                  // Forward declaration of ERROR_CODES, like timeouts, returned through the physical layer


  bool                    read(READ_DATA_ID                   msgID,
                                uint16_t &                    value);

  bool                    read(READ_DATA_ID                   msgID,
                                int16_t &                     value);

  bool                    read(READ_DATA_ID                   msgID,
                                uint8_t &                     valueMSB,
                                uint8_t &                     valueLSB);

  bool                    read(READ_DATA_ID                   msgID,
                                int8_t &                      valueMSB,
                                int8_t &                      valueLSB);

  bool                    read(READ_DATA_ID                   msgID,
                                float &                       value);

  bool                    write(WRITE_DATA_ID                 msgID,  
                                uint16_t                      value);

  bool                    write(WRITE_DATA_ID                 msgID,  
                                uint8_t                       valueMSB,
                                uint8_t                       valueLSB);

  bool                    write(WRITE_DATA_ID                 msgID,
                                float                         value);

  bool                    readWrite(READ_WRITE_DATA_ID        msgID,
                                    uint8_t                   valueMSB,
                                    uint8_t &                 valueLSB);

  ERROR_CODES             error();


  enum class    READ_WRITE_DATA_ID {
    // Class 1 : Control and Status Information
    STATUS                          = 0,        // flag8, flag8     Mandatory; Primary status, secondary status

    // Class 3 : Remote Commands
    COMMAND_CODE                    = 4,        // u8, u8           Command code / Response to command

    // Class 6 : Transparent Secondary Parameters
    TSP_COMMAND                     = 11,       // u8, u8           Index number of following TSP, Value of the referenced TSP

    // Class 7 : Fault History Data
    FAULT_BUFFER_DATA               = 13,       // u8, u8           Index number of Fault Buffer entry, Value of the referenced Fault Buffer entry

    // Incomplete information for all DATA-IDs below. If these DATA-IDs are R, W or R/W is unknown. Also the data type is unknown and deducted from the name. These DATA-IDs are not ordered by class
    // Where applicable and available flags and masks are also defined below

    // HVAC specific DATA-IDs (ventilation / heat recovery)
    HVAC_STATUS                     = 70,       // flag8, flag8     Primary status, secondary status

    // Solar specific DATA-IDs
    SOLAR_STATUS                    = 101,      // flag8, flag8?    MSB Primary Solar Storage Mode, LSB Secondary Solar Storage Mode
  };


  enum class    READ_DATA_ID {
    // Class 1 : Control and Status Information
    FAULT_FLAGS                     = 5,        // flag8, u8        Application-specific fault flags and OEM fault code
    OEM_DIAGNOSTIC                  = 115,      // u16              An OEM-specific diagnostic/service code

    // Class 2 : Configuration Information
    SECONDARY_CONFIGURATION         = 3,        // flag8, u8        Mandatory; Secondary Configuration Flags / MemberID Code of the secondary device
    OPENTHERM_VERSION_SECONDARY     = 125,      // f8.8             The implemented version of the OpenTherm Protocol Specification in the secondary device
    SECONDARY_PRODUCT_VERSION       = 127,      // u8, u8           The secondary device product version number and type as defined by the manufacturer

    // Class 4 : Sensor and Informational Data
    RELATIVE_MODULATION_LEVEL       = 17,       // f8.8             Mandatory; Percent modulation between min and max modulation levels. i.e. 0% = Minimum modulation level and 100% = Maximum modulation level (%)
    CH_WATER_PRESSURE               = 18,       // f8.8             Water pressure of the boiler CH circuit (bar)
    DHW_FLOW_RATE                   = 19,       // f8.8             Water flow rate through the DHW circuit (l/min)
    DAY_TIME                        = 20,       // special, u8      Day of Week and Time of Day; special: bit 7,6,5 day of week (1=Monday, etc...., 0=no DoW info available); bit 4,3,2,1,0 hours, LSB is minutes
    DATE                            = 21,       // u8, u8           Calendar date: Month, Day of month
    YEAR                            = 22,       // u16              Calendar year; note : 1999-2099 will normally be sufficient
    BOILER_WATER_TEMP               = 25,       // f8.8             Mandatory; Flow water temperature from boiler (°C)
    DHW_TEMPERATURE                 = 26,       // f8.8             Domestic hot water temperature (°C)
    OUTSIDE_TEMPERATURE             = 27,       // f8.8             Outside air temperature (°C)
    RETURN_WATER_TEMPERATURE        = 28,       // f8.8             Return water temperature to boiler (°C)
    SOLAR_STORE_TEMPERATURE         = 29,       // f8.8             Solar storage temperature (°C)
    SOLAR_COLLECTOR_TEMPERATURE     = 30,       // f8.8             Solar collector temperature (°C)
    FLOW_TEMPERATURE_CH2            = 31,       // f8.8             Flow water temperature of the second central heating circuit (°C)
    DHW2_TEMPERATURE                = 32,       // f8.8             Domestic hot water temperature 2 (°C)
    EXHAUST_TEMPERATURE             = 33,       // s16              Exhaust temperature (°C)
    BURNER_STARTS                   = 116,      // u16              Number of starts burner. Reset by writing zero is optional for the secondary device
    CH_PUMP_STARTS                  = 117,      // u16              Number of starts CH pump. Reset by writing zero is optional for the secondary device
    DHW_PUMP_VALVE_STARTS           = 118,      // u16              Number of starts DHW pump/valve. Reset by writing zero is optional for the secondary device
    DHW_BURNER_STARTS               = 119,      // u16              Number of starts burner in DHW mode. Reset by writing zero is optional for the secondary device
    BURNER_OPERATION_HOURS          = 120,      // u16              Number of hours that burner is in operation (i.e. flame on). Reset by writing zero is optional for the secondary device
    CH_PUMP_OPERATION_HOURS         = 121,      // u16              Number of hours that CH pump has been running. Reset by writing zero is optional for the secondary device
    DHW_PUMP_VALVE_OPERATION_HOURS  = 122,      // u16              Number of hours that DHW pump has been running or DHW valve has been opened. Reset by writing zero is optional for the secondary device
    DHW_BURNER_OPERATION_HOURS      = 123,      // u16              Number of hours that burner is in operation during DHW mode. Reset by writing zero is optional for the secondary device

    // Class 5 : Pre-Defined Remote Boiler Parameters
    REMOTE_PARAMETER                = 6,        // flag8, flag8     Remote boiler parameter transfer-enable flags, read/write flags
    DHW_SETPOINT_BOUNDS             = 48,       // s8, s8           Upper bound for adjustment of DHW setp (°C), Lower bound for adjustment of DHW setp (°C)
    CH_SETPOINT_BOUNDS              = 49,       // s8, s8           Upper bound for adjustment of maxCH setp (°C), Lower bound for adjustment of maxCH setp (°C)
    OTC_CURVE_BOUNDS                = 50,       // s8, s8           Upper / lower bound
    DHW_SETPOINT                    = 56,       // f8.8             Domestic hot water temperature setpoint (Remote parameter 1) (°C)
    MAX_CH_WATER_SETPOINT           = 57,       // f8.8             Maximum allowable CH water setpoint (Remote parameter 2) (°C) 
    OTC_CURVE_RATIO                 = 58,       // f8.8             OTC heat curve ratio (Remote parameter 3)

    // Class 6 : Transparent Secondary Parameters
    NUMBER_OF_TSPS                  = 10,       // u8, u8           Number of transparent-secondary-parameter supported by the secondary device, -Reserved-

    // Class 7 : Fault History Data
    FAULT_BUFFER_SIZE               = 12,       // u8, u8           The size of the fault history buffer, -Reserved-

    // Class 8 : Control of Special Applications
    MAX_BOILER_CAPACITY_MIN_MOD_LEV = 15,       // u8, u8           MSB : max. boiler capacity (0..255kW), LSB : min. modulation level (0..100%) expressed as a percentage of the maximum capacity
    CH_SETPOINT_OVERRIDE            = 9,        // f8.8             Remote override room setpoint (0 is no override, 1..30 is remote override room setpoint)
    REMOTE_OVERRIDE_FUNCTION        = 100,      // flag8, u8        Bit 0: Manual change priority; bit 1: Program change priority, HSB -Reserved-


    // Incomplete information for all DATA-IDs below. If these DATA-IDs are R, W or R/W is unknown. Also the data type is unknown and deducted from the name. These DATA-IDs are not ordered by class
    // Where applicable and available flags and masks are also defined below

    // Boiler specific DATA-IDs
    BOILER_HEAT_EXCHANGER_TEMPERATURE = 34,     // f8.8             Boiler heat exchanger temperature (°C)
    BOILER_FAN_SPEED_SETPOINT_VALUE = 35,       // ?                Boiler fan speed Setpoint and actual value
    ELECTRICAL_CURRENT_BURNER_FLAME = 36,       // ?                Electrical current through burner flame (μA)

    // HVAC specific DATA-IDs (ventilation / heat recovery)
    HVAC_RELATIVE_VENT_SETPOINT     = 71,       // f8.8             Relative ventilation position (0-100%)
    HVAC_FAULT_FLAGS                = 72,       // flag8, u8        Application-specific fault flags and OEM fault code
    HVAC_OEM_DIAGNOSTIC_CODE        = 73,       // u16              An OEM specific diagnostic/service code
    HVAC_SECONDARY_CONFIGURATION    = 74,       // flag8, u8        Secondary Configuration Flags / MemberID Code of the secondary device
    HVAC_OPENTHERM_VERSION_SECONDARY= 75,       // f8.8             The implemented version of the OpenTherm Protocol Specification in the secondary device
    HVAC_SECONDARY_PRODUCT_VERSION  = 76,       // u8, u8           The secondary device product version number and type as defined by the manufacturer
    HVAC_RELATIVE_VENTILATION       = 77,       // f8.8             Relative ventilation (0-100%)
    HVAC_RELATIVE_HUMIDITY_EXHAUST  = 78,       // f8.8             Relative humidity exhaust air (0-100%)
    HVAC_CO2_LEVEL_EXHAUST_AIR      = 79,       // ?                CO2 level exhaust air (0-2000 ppm)
    HVAC_SUPPLY_INLET_TEMPERATURE   = 80,       // f8.8             Supply inlet temperature (*C)
    HVAC_SUPPLY_OUTLET_TEMPERATURE  = 81,       // f8.8             Supply outlet temperature (*C)
    HVAC_EXHAUST_INLET_TEMPERATURE  = 82,       // f8.8             Exhaust inlet temperature (*C)
    HVAC_EXHAUST_OUTLET_TEMPERATURE = 83,       // f8.8             Exhaust outlet temperature (*C)
    HVAC_EXHAUST_FAN_SPEED          = 84,       // u16?             Exhaust fan speed (rpm)
    HVAC_SUPPLY_FAN_SPEED           = 85,       // u16?             Supply fan speed (rpm)
    HVAC_REMOTE_PARAMETER           = 86,       // u8, u8?          MSB Remote parameter transfer enable nominal ventilation value, LSB Remote parameter read/write nominal ventilation value
    HVAC_NOMINAL_RELATIVE_VENTILATION = 87,     // f8.8             Nominal relative value for ventilation (0-100%)
    HVAC_NUMBER_OF_TSPS             = 88,       // u8, u8?          Number of transparent-secondary-parameter supported by the secondary device, -Reserved-
    HVAC_TSP_COMMAND                = 89,       // u8, u8           Index number of following TSP, Value of the referenced TSP
    HVAC_FAULT_BUFFER_SIZE          = 90,       // u8, u8?          The size of the fault history buffer
    HVAC_FAULT_BUFFER_DATA          = 91,       // u8, u8           Index number of Fault Buffer entry, Value of the referenced Fault Buffer entry
    HVAC_RF_STRENGTH_BATTERY_LEVEL  = 98,       // u8, u8?          For a specific RF sensor RF strength and battery level
    HVAC_OPERATING_MODE             = 99,       // ?                Operating mode HC1, HC2 / Operating mode DHW

    // Solar specific DATA-IDs
    SOLAR_FAULT_FLAGS               = 102,      // flag8, u8        Application-specific fault flags and OEM fault code
    SOLAR_SECONDARY_CONFIGURATION   = 103,      // flag8, u8        Secondary Configuration Flags / MemberID Code of the secondary device
    SOLAR_SECONDARY_PRODUCT_VERSION = 104,      // u8, u8           The secondary device product version number and type as defined by the manufacturer
    SOLAR_NUMBER_OF_TSPS            = 105,       // u8, u8?         Number of transparent-secondary-parameter supported by the secondary device, -Reserved-
    SOLAR_TSP_COMMAND               = 106,       // u8, u8          Index number of following TSP, Value of the referenced TSP
    SOLAR_FAULT_BUFFER_SIZE         = 107,       // u8, u8?         The size of the fault history buffer
    SOLAR_FAULT_BUFFER_DATA         = 108,       // u8, u8          Index number of Fault Buffer entry, Value of the referenced Fault Buffer entry

    // Electricity specific DATA-IDs
    PRODUCER_STARTS                 = 109,      // u16              Electricity producer starts
    PRODUCER_HOURS                  = 110,      // u16              Electricity producer hours
    PRODUCTION                      = 111,      // u16              Electricity production
    CUMULATIVE_PRODUCTION           = 112,      // u16              Electricity cumulative production

    // Boiler specific DATA-IDs
    UNSUCCESSFUL_BURNER_STARTS      = 113,      // u16              Number of unsuccessful burner starts
    FLAME_SIGNAL_TOO_LOW            = 114,      // u16              Number of times flame signal was too low
  };


  enum class    WRITE_DATA_ID {
    // Class 1 : Control and Status Information
    CONTROL_SETPOINT_CH             = 1,        // f8.8             Mandatory; Control setpoint (CH  water temperature setpoint) (°C)
    CONTROL_SETPOINT_CH2            = 8,        // f8.8             Control setpoint for 2nd CH circuit (°C)

    // Class 2 : Configuration Information
    PRIMARY_CONFIGURATION           = 2,        // flag8, u8        Primary Configuration Flags / MemberID Code of the primary device
    OPENTHERM_VERSION_PRIMARY       = 124,      // f8.8             The implemented version of the OpenTherm Protocol Specification in the primary device
    PRIMARY_PRODUCT_VERSION         = 126,      // u8, u8           The primary device product version number and type as defined by the manufacturer

    // Class 4 : Sensor and Informational Data
    ROOM_SETPOINT                   = 16,       // f8.8             Current room temperature setpoint (°C)
    DAY_TIME                        = 20,       // special, u8      Day of Week and Time of Day; special: bit 7,6,5 day of week (1=Monday, etc...., 0=no DoW info available); bit 4,3,2,1,0 hours, LSB is minutes
    DATE                            = 21,       // u8, u8           Calendar date: Month, Day of month
    YEAR                            = 22,       // u16              Calendar year; note : 1999-2099 will normally be sufficient
    ROOM_SETPOINT_CH2               = 23,       // f8.8             Current room Setpoint for 2nd CH circuit (°C)
    ROOM_TEMPERATURE                = 24,       // f8.8             Current sensed room temperature (°C)
    BURNER_STARTS                   = 116,      // u16              Number of starts burner. Reset by writing zero is optional for the secondary device
    CH_PUMP_STARTS                  = 117,      // u16              Number of starts CH pump. Reset by writing zero is optional for the secondary device
    DHW_PUMP_VALVE_STARTS           = 118,      // u16              Number of starts DHW pump/valve. Reset by writing zero is optional for the secondary device
    DHW_BURNER_STARTS               = 119,      // u16              Number of starts burner in DHW mode. Reset by writing zero is optional for the secondary device
    BURNER_OPERATION_HOURS          = 120,      // u16              Number of hours that burner is in operation (i.e. flame on). Reset by writing zero is optional for the secondary device
    CH_PUMP_OPERATION_HOURS         = 121,      // u16              Number of hours that CH pump has been running. Reset by writing zero is optional for the secondary device
    DHW_PUMP_VALVE_OPERATION_HOURS  = 122,      // u16              Number of hours that DHW pump has been running or DHW valve has been opened. Reset by writing zero is optional for the secondary device
    DHW_BURNER_OPERATION_HOURS      = 123,      // u16              Number of hours that burner is in operation during DHW mode. Reset by writing zero is optional for the secondary device

    // Class 5 : Pre-Defined Remote Boiler Parameters
    DHW_SETPOINT                    = 56,       // f8.8             Domestic hot water temperature setpoint (Remote parameter 1) (°C)
    MAX_CH_WATER_SETPOINT           = 57,       // f8.8             Maximum allowable CH water setpoint (Remote parameter 2) (°C) 
    OTC_CURVE_RATIO                 = 58,       // f8.8             OTC heat curve ratio (Remote parameter 3) (°C)

    // Class 6 : Transparent Secondary Parameters
    TSP_COMMAND                     = 11,       // u8, u8           Index number of following TSP, Value of the referenced TSP

    // Class 8 : Control of Special Applications
    COOLING_CONTROL                 = 7,        // f8.8             Signal for cooling plant (%)
    MAX_MODULATION_LEVEL            = 14,       // f8.8             Mandatory; Maximum relative boiler modulation level setting for sequencer and off-low & pump control applications (%)


    // Incomplete information for DATA-IDs below. If these DATA-IDs are R, W or R/W is unknown. Also the data type is unknown and deducted from the name
    // Boiler DATA-ID
    ROOM_TEMPERATURE_CH2            = 37,       // f8.8             Room temperature for second CH unit(°C)
  };


  // Flags used by ::status(primaryFlags, secondaryFlags); The flags starting with PRIMARY_ are sent from the thermostat to the boiler and the flgas starting with SECONDARY_ are received 
  // from the boiler
  enum class    STATUS_FLAGS {
    // Primary device is MSB
    PRIMARY_CH_ENABLE               = (0b00000001),           // CH is Central Heating
    PRIMARY_DHW_ENABLE              = (0b00000010),           // DHW is Domestic Hot Water
    PRIMARY_COOLING_ENABLE          = (0b00000100),
    PRIMARY_OTC_ENABLE              = (0b00001000),           // OTC is Outside Temperature Compensation
    PRIMARY_CH2_ENABLE              = (0b00010000),

    // Secondary device is LSB
    SECONDARY_FAULT_INDICATION      = (0b00000001),
    SECONDARY_CH_MODE               = (0b00000010),
    SECONDARY_DHW_MODE              = (0b00000100),
    SECONDARY_FLAME_STATUS          = (0b00001000),
    SECONDARY_COOLING_STATUS        = (0b00010000),
    SECONDARY_CH2_MODE              = (0b00100000),
    SECONDARY_DIAGNOSTIC_IND        = (0b01000000),
  };


  // Configuration flags returned by calling ::read(OpenTherm::READ_DATA_ID::SECONDARY_CONFIGURATION, configurationFlags, memberID);
  enum class    CONFIGURATION_FLAGS {
    SECONDARY_DHW_PRESENT           = (0b00000001),
    SECONDARY_CONTROL_TYPE          = (0b00000010),
    SECONDARY_COOLING               = (0b00000100),
    SECONDARY_DHW                   = (0b00001000),  
    SECONDARY_LOW_OFF_PUMP_CTRL     = (0b00010000),
    SECONDARY_CH2_PRESENT           = (0b00100000),
  };


  // A few known member IDs returned by calling ::read(OpenTherm::READ_DATA_ID::SECONDARY_CONFIGURATION, configurationFlags, memberID);
  enum          MEMBER_IDS: uint8_t {                         // May be extended with other manufacturer OpenTherm member IDs. Maybe incorrect
    AWB                             = 2,
    BRINK                           = 2,
    ATAG                            = 4,
    BROTJE                          = 4,
    ELCO                            = 4,
    GEMINOX                         = 4,
    ITHO_DAALDEROP                  = 5,
    IDEAL                           = 6,
    BOSCH                           = 8,
    HOVAL                           = 8,
    FERROLI                         = 9,
    REMEHA                          = 11,
    DE_DIETRICH                     = 11,
    UNICAL                          = 16,
    BULEX                           = 24,
    VAILLANT                        = 24,
    BAXI                            = 27,
    DAALDEROP                       = 29,
    VIESSMANN                       = 33,
    NEFIT                           = 131,
    INTERGAS                        = 173,
  };


  // Fault flags returned by calling ::read(OpenTherm::READ_DATA_ID::FAULT_FLAGS, faultFlags, OEMFaultCode);
  enum class    FAULT_FLAGS {
    SERVICE_REQUEST                 = (0b00000001),
    LOCKOUT_RESET                   = (0b00000010),
    LOW_WATER_PRESS                 = (0b00000100),
    GAS_FLAME                       = (0b00001000),
    AIR_PRESS                       = (0b00010000),
    WATER_OVER_TEMP                 = (0b00100000),
  };


  // Remote parameter flags returned by calling ::read(OpenTherm::READ_DATA_ID::REMOTE_PARAMETER, remoteParameterTEFlags, remoteParameterRWFlags);
  enum class    REMOTE_PARAMETER_FLAGS {
    TRANSFER_ENABLE_DHW_SETPOINT    = (0b00000001),
    TRANSFER_ENABLE_MAX_CH_SETPOINT = (0b00000010),

    READ_WRITE_DHW_SETPOINT         = (0b00000001),
    READ_WRITE_MAX_CH_SETPOINT      = (0b00000010),
  };



  // Remote parameter flags returned by calling ::read(OpenTherm::READ_DATA_ID::REMOTE_OVERRIDE_FUNCTION, reserved, remoteOverrideFlags);
  enum class    REMOTE_OVERRIDE_FLAGS {
    MANUAL_CHANGE_PRIORITY          = (0b00000001),
    REMOTE_CHANGE_PRIORITY          = (0b00000010),
  };


  // Remote parameter flags returned by calling ::readWrite(OpenTherm::READ_WRITE_DATA_ID::COMMAND_CODE, remoteCommand, cmdResponseCode);
  enum class    REMOTE_COMMANDS {
    BLOR                            = (1),                    // Boiler Lock-out Reset command
    CHWF                            = (2),                    // CH water filling
  };


  // Flags used by ::readWrite(OpenTherm::READ_WRITE_DATA_ID::HVAC_STATUS, primaryFlags, secondaryFlags); The flags starting with PRIMARY_ are sent from the thermostat to the HVAC
  // and the flags starting with SECONDARY_ are received from the HVAC. This is comparable to the ::status() call for a boiler.
  enum class    HVAC_STATUS_FLAGS {
    // Primary device is MSB
    PRIMARY_VENTILATION_ENABLE      = (0b00000001),
    PRIMARY_BYPASS_POSTION          = (0b00000010),
    PRIMARY_BYPASS_MODE             = (0b00000100),
    PRIMARY_FREE_VENTILATION_MODE   = (0b00001000),

    // Secondary device is LSB
    SECONDARY_FAULT_INDICATION      = (0b00000001),
    SECONDARY_VENTILATION_MODE      = (0b00000010),
    SECONDARY_BYPASS_STATUS         = (0b00000100),
    SECONDARY_BYPASS_AUTOMATIC_STATUS= (0b00001000),
    SECONDARY_FREE_VENTILATION_MODE = (0b00010000),
    SECONDARY_DIAGNOSTIC_IND        = (0b00100000),
  };


  // Configuration flags returned by calling ::read(OpenTherm::READ_DATA_ID::HVAC_SECONDARY_CONFIGURATION, configurationFlags, memberID);
  enum class    HVAC_CONFIGURATION_FLAGS {
    SECONDARY_SYSTEM_TYPE           = (0b00000001),
    SECONDARY_BYPASS                = (0b00000010),
    SECONDARY_SPEED_CONTROL         = (0b00000100),
  };




  enum class    SOLAR_STATUS_FLAGS {
    // Priamry device is MSB
    PRIMARY_MODE                    = (0b00000111),

    // Secondary device is LSB
    SECONDARY_FAULT_INDICATION      = (0b00000001),
    SECONDARY_MODE                  = (0b00001110),
    SECONDARY_STATUS                = (0b00110000),
  };


  enum class    SOLAR_MODE_FLAGS_AND_MASKS {
    SYSTEM_TYPE                     = (0b00000001),
    BYPASS                          = (0b00000010),
    SPEED_CONTROL                   = (0b00000100),
  };


  enum class    SOLAR_SECONDARY_CONFIGURATION_FLAGS {
    SECONDARY_SYSTEM_TYPE           = (0b00000001),
  };


  // ::error(); returns the result of the latest call to ::read();, ::write(); or ::readWrite();
  enum class    ERROR_CODES {
    OK,                                                       // Everything is OK
    UNKNOWN_DATA_ID,                                          // The DATA-ID sent by the primary to the secondary is not supported by the secondary
    INVALID_DATA,                                             // The DATA-ID sent by the primary to the secondary is supported but the sent value is out of bounds
    SEND_TIMEOUT,                                             // The primary could not send within timeout period (should not occur if timeouts are reasonable)
    RECEIVE_TIMEOUT,                                          // The secondary did not respond within timeout period
    PARITY_ERROR,                                             // The secondary's response had a parity error
    UNKNOWN_ERROR,                                            // Unknown error (should not occur)
  };


private:
  bool                    _execute(OTDataLinkLayer &          data);

  OTPhysicalLayer *       _OTP;

  uint8_t                 _rxPin;
  uint8_t                 _txPin;

  time_t                  _timeoutMs;
  bool                    _primary;

  ERROR_CODES             _lastError;
};


class                     OTDataLinkLayer {
public:
  enum class              MSG_TYPE;                           // Forward declaration


                          OTDataLinkLayer();

                          OTDataLinkLayer(uint32_t            frame);

  void                    set(uint32_t                        frame);

  void                    set(MSG_TYPE                        msgType,
                              uint8_t                         dataID,
                              uint16_t                        value);

  void                    set(MSG_TYPE                        msgType,
                              uint8_t                         dataID,
                              uint8_t                         valueMSB,
                              uint8_t                         valueLSB);

  bool                    parity();

  MSG_TYPE                type();

  uint8_t                 dataID();

  uint16_t                value();

  uint8_t                 valueMSB();

  uint8_t                 valueLSB();

  uint32_t                frame();

  bool                    isValid();

  bool                    dataInvalid();

  bool                    unknownDataID();


  enum class              MSG_TYPE {
    PRIMARY_TO_SECONDARY_READ_DATA       = (0b0000000UL << 24),        // value >> 28 := 0
    PRIMARY_TO_SECONDARY_WRITE_DATA      = (0b0010000UL << 24),        // value >> 28 := 1
    PRIMARY_TO_SECONDARY_INVALID_DATA    = (0b0100000UL << 24),        // value >> 28 := 2
    PRIMARY_TO_SECONDARY_RESERVED        = (0b0110000UL << 24),        // value >> 28 := 3

    SECONDARY_TO_PRIMARY_READ_ACK        = (0b1000000UL << 24),        // value >> 28 := 4
    SECONDARY_TO_PRIMARY_WRITE_ACK       = (0b1010000UL << 24),        // value >> 28 := 5
    SECONDARY_TO_PRIMARY_DATA_INVALID    = (0b1100000UL << 24),        // value >> 28 := 6
    SECONDARY_TO_PRIMARY_UNKNOWN_DATA_ID = (0b1110000UL << 24)         // value >> 28 := 7
  };

private:
  uint32_t                _frame;

  bool                    _parity(uint32_t                    frame);

};


class           OTPhysicalLayer {
public:
                          OTPhysicalLayer(uint8_t             rxPin,
                                          uint8_t             txPin,
                                          bool                primary);

                          ~OTPhysicalLayer();

  bool                    send(uint32_t                       frame);

  bool                    receive(uint32_t &                  frame);

  void                    reset();

#if defined(ESP32)
  void IRAM_ATTR          handleInterrupt();
#elif defined(ESP8266)
  void ICACHE_RAM_ATTR    handleInterrupt();
#else
  void                    handleInterrupt();
#endif

private:
  void                    sendBit(uint8_t                     val);

  volatile uint32_t       _frame;
  uint32_t                _lastSentTimestampMs;
  volatile uint32_t       _lastReceivedTimestampMs;

  uint8_t                 _rxPin;
  uint8_t                 _txPin;
  bool                    _primary;

  enum class              STATE {
                          INVALID,
                          READY,
                          WAITING,
                          START_BIT,
                          RECEIVING,
  };

  volatile STATE          _state = STATE::INVALID;
};